| Itemプロジェクト | Specifications仕様 |
| Contact Arrangement接点形式 | 1 Form A(normally open)1グループ常時オープン |
| Contact Resistance(Initial)接触抵抗(初期値) | ≤0.2mΩ @ 200A |
| Rated Load Current定格電流 | 300 A(@100 mm 2 Busbar銅製列) |
| Min.loading最小使用負荷 | 6Vd.c.,1A |
| Max.Breaking Current最大分断電流 | 2500 A(850 Vd.c.)1 op回 |
Insulating Property
绝缘性能 | Dielectric Strength媒体耐圧 | 3000 VAC 1 min,between open contacts接点間 |
| 3000 VAC 1 min,between coil and contact接点とコイル間 |
| Insulation Resistance絶縁抵抗 | 1000 MΩat 1000 VDC,between open contacts接点間 |
| 1000 MΩat 1000 VDC,between coil and contact接点とコイル間 |
Environment Parameter
环境参数 | Operating Temperature動作温度 | -40℃~85℃ |
| Operating Humidity動作湿度 | 20% RH ~85%RH |
| Storage Temperature保存温度 | -40℃~85℃ |
| Storage Humidity貯蔵湿度 | 20% RH ~85%RH |
| Endurance耐久性 | Electric endurance電気耐久性 | オン:7.5×10 ^ 4回(20 Vd.c.,140 A) |
| 分断:1000 Vd.c.、300 A 300回(0.6 s on/5.4 s off) |
| 分断:0.2 s on 1回(450 Vd.c.,2000 A) |
| 分断:0.2 s on 1回(500 Vd.c.,1800 A) |
| Short circuit耐短絡 | 500Vd.c., 8000A t≤5ms,1回(煙が出ない、発火しない、爆発しない) |
| 電流耐性(85℃) | 300A,持続 |
| 350A, 8min |
| 500A, 2min |
| 900A, 25s |
| 1000A, 20s |
| 機械耐久性 | 2 x 10 ^ 5回 |
Time Parameter 时间参数 | 吸入時間操作時間 | ≤30ms |
| リリース時間リリース時間 | ≤10ms |
PWM Parameter PWM 参数 | くどうモード | 電流フィードバック閉ループ制御 |
| きゅうちゃくでんりゅう | 2A |
| ほじでんりゅう | 0.8A |
| 400KHZ±12% |
| コイルサンプリング抵抗 | 0.05Ω |
最大逆電圧maximum reverse voltage | <30V |